AC/DC Hipot Megohmmeters

Is toegevoegd aan uw winkelmandje

Ga naar winkelmandje

AC/DC Hipot Megohmmeters

Dit product is niet online te bestellen. Neem contact met ons op voor advies en bestelmogelijkheden.

Product description

Model-types

Model PAD56
Model PM15-2
Model PM5
Model PM20

Model specifications

ModelPAD56PM15-2
Insulation resistanceValues up to 1,000,000 MΩ
At test voltages of 2.5 kV or 5 kV DC
(a scale factor for other test voltages is provided)
Values up to 3,000,000 MΩ
At test voltages of 5 kV, 10 kV, 15 kV DC
(a scale factor for other test voltages is provided)
Leakage current.01-5,000 microamps DC
.1-5 milliamps AC
.01-2,000 microamps DC
Input120 VAC, 60 Hz, single phase, .3 Amps or 230 VAC,
50/60 Hz, single phase, .15 Amps
120 VAC, 60 Hz, single phase, 1 Amps or 230 VAC,
50/60 Hz, single phase, .5 Amps
Output≈0-5 kV AC, 0-5 milliamps
≈0-6 kV DC, 0-5 milliamps Negative output, positive ground
≈0-15 kV DC, 0-2 milliamps Negative output, positive ground
Volt meter2-ranges: 0-3/6 kV2-ranges: 0-7.5/15 kV
Current meter0-5 milliamps AC
0-.5/5/50/500/5000 microamps DC
0-.5/5/50/500/5000 microamps DC
Resistance MΩ @ 2500 V5-50
5-500
50-5,000
500-50,000
5,000-500,000
N.A.
Resistance MΩ @ 5000 V1-100
10-1,000
100-10,000
1,000-100,000
10,000-1,000,000
1-100
10-1,000
100-10,000
1,000-100,000
10,000-1,000,000
Resistance MΩ @ 10000 VN.A.2-200
20-2,000
200-20,000
2,000-200,000
20,000-2,000,000
Resistance MΩ @ 15000 VN.A.3-300
30-3,000
300-30,000
3,000-300,000
30,000-3,000,000
Safety
& Design features
• Adjustable overcurrent trip point
• Zero start interlock
• Guard circuit for stray leakage current bypass
• Multi-range current and voltage measurement
• Surge and transient protection
• Adjustable output current limit”
Unique features• Internal discharge device• Low ripple 0.4% peak-peak at full output
Dimensions and weightL 457 mm
W 279 mm
H 292 mm
WT 10 kg
L 457 mm
W 279 mm
H 292 mm
WT 7 kg
Cable TypeCable included with PAD56 and PM15-2
Input
10’ (3 m) Standard modular 3-wire cord mating to fused input module
High Voltage Output10’ (3 m) attached shielded cable with clip and insulator
(removable on model PAD10-25)”
Return Lead10’ (3 m) red lead with insulated clip
Ground Lead10’ (3 m) green lead with insulated clip
ModelPM5PM20
INSULATION RESISTANCEValues up to 10,000,000 MΩ
At test voltages of 0.5 kV, 1 kV, 2.5 kV, 5 kV DC
(a scale factor for other test voltages is provided)
Values up to 4,000,000 MΩ
At test voltages of 5 kV, 10 kV, 15 kV, 20 kV DC
(a scale factor for other test voltages is provided)
Input
Internal Rechargable Battery or
Input Power Cord 100-240 VAC, 50/60 Hz
Internal Rechargable Battery or
Input Power Cord 100-240 VAC, 50/60 Hz
Output0.5 kV, 1 kV, 2.5 kV, 5 kV DC5 kV, 10 kV, 15 kV, 20 kV DC
Metering4” analog meter Accuracy: ±2% of full scale4” analog meter Accuracy: ±2% of full scale
CurrentShort circuit 1 mA ±2%Short circuit 500 µA ±5%
Internal current limiting resistance500 kΩ @ 500 V
1 MΩ @ 1 kV
2.5 MΩ @ 2.5 kV
5 MΩ @ 5 kV
10 MΩ @ 5 kV
20 MΩ @ 10 kV
30 MΩ @ 15 kV
40 MΩ @ 20 kV
Dimensions and weightL 279 mm
W 254 mm
H 127 mm
WT 4 kg
L 381 mm
W 305 mm
H 178 mm
WT 10 kg
Unique Features• Guard terminal
• Rechargable battery
• Multiple scales for greater accuracy
Cables2 Measuring test leads 6’ (1.8 m)
1 Guard test lead
1 Charging power cord

Werkelijke specificaties kunnen afwijken van de op deze website vermelde specificaties. Aan de op deze website vermelde specificaties kunnen geen rechten worden ontleend.