15-200 kVAC Hipot test set

Has been added to your shopping cart

Go to shopping cart

15-200 kVAC Hipot test set

This product cannot be ordered online. Contact us for advice and ordering options.

Product description

Summary

The 6CB and 6CP line of hipot testers offer 2 piece mobile hipots for field and laboratory use with a high accuracy guard mode reducing stray Capacitive currents. The 6CP range offers digital metering and manually dial able over current protection for ease of use. The 6CB range offers 7 inch touchscreen display for operation, and comes with a lot of additional features enabled by the intelligence added to the system.

Safety and design features of the 6CB Range

Safety and design features of the 6CP Range

scale
Model6CB30/15-3 & 6CP30/15-36CB50/10-3 & 6CP50/10-3 6CB100/50-7.5 & 6CP100/50-7.5 6CB120/60-7.5 & 6CP120/60-7.5
Input voltage and current220-240V, 8A 220-240V, 8A 220-240V, 15A220-240V, 15A
Input frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
Output Voltage and current0-15 kV, 200 mA
0-30 kV, 100 mA
0-10 kV 300 mA.
0-50 kV 60 mA.
0-50 kV 150 mA.
0-100 kV 75 mA.
0-60 kV, 125 mA.
0-120 kV, 62.5 mA.
Dutycycles3 kVA 5 mins on 15 mins off
2 kVA 15 mins on 60 mins off
3 kVA 60 mins on 60 mins off
3 kVA 5 mins on 15 mins off
2 kVA 15 mins on 60 mins off
3 kVA 60 mins on 60 mins off
7.5 kVA 5 mins on 15 mins off
5 kVA 15 mins on 60 mins off
3 kVA 60 mins on 60 mins off
7.5 kVA 5 mins on 15 mins off
5 kVA 15 mins on 60 mins off
3 kVA 60 mins on 60 mins off
Compensation50% Inductive Reactive 50% Inductive Reactive 66% Inductive + Selectable
Capacitive Preload
66% Inductive + Selectable
Capacitive Preload
Measurement0.8% Reading +0.2% full scale 0.8% Reading +0.2% full0.8% Reading +0.2% full scale
Voltmeter Range(s)0-15/30 kV 0-10/50 kV 0-50/100 kV 0-60/120 kV
Currentmeter ranges 0-200 μA/2 mA/ 20 mA/ 200 mA 0-200 μA/2 mA/ 20 mA/ 300 m A 0-200 μA/ 2 mA/ 20 mA/ 200 mA 0-200 μA/ 2 mA/ 20 mA/ 200 mA
OutputHV Electrode HV Electrode HV Electrode HV Electrode
PD Level<10 pC standard, < 3pC optionally <10 pC standard, < 3pC optionally <10 pC standard, < 3pC optionally <10 pC standard, < 3pC optionally
(up to 100 kV)
Model6CB100/50-10 & 6CP100/50-10 6CB120/60-10 & 6CP120/60-10 6CB200/100-10 & 6CP200/100-10
Input voltage and current220-240V, 30A 220-240V, 30A 220-240V, 25A
Input frequency 50/60 Hz 50/60 Hz 50/60 Hz
Output Voltage and current0-15 kV, 200 mA
0-30 kV, 100 mA
0-10 kV 300 mA.
0-50 kV 60 mA.
0-50 kV 150 mA.
0-100 kV 75 mA.
Dutycycles10 kVA 5 mins on 15 mins
7.5 kVA 15 mins on 60 mins off
5 kVA 60 mins on 60 mins off
10 kVA 5 mins on 15 mins
7.5 kVA 15 mins on 60 mins off
5 kVA 60 mins on 60 mins off
10 kVA 5 mins on 15 mins
7.5 kVA 15 mins on 60 mins off
5 kVA 60 mins on 60 mins off
Compensation50% inductive Reactive 50% Inductive Reactive 50% inductive Reactive
Measurement0.8% Reading +0.2% full scale 0.8% Reading +0.2% full scale0.8% Reading +0.2% full scale
Voltmeter Range(s)0-50/100 kV 0-60/120 kV0-100/200 kV
Currentmeter ranges 0-200 μA/ 2 mA/ 20 mA/ 200 mA0-200 μA/ 2 mA/ 20 mA/ 200 mA0-200 μA/ 2 mA/ 20 mA/ 200 mA
OutputHV Electrode HV Electrode HV Electrode
PD Level<10 pC standard, < 3pC optionally<10 pC standard, < 3pC optionally
(up to 100 kV)
<10 pC standard, < 3pC optionally
(up to 100 kV)

Options

6CB
6CB30/15-3
Options
6CP100/200
6CP100/50-7.5
6CP

Actual specifications may differ from those stated on this website. No rights can be derived from the specifications stated on this website.

Back to top